Shell Tellus S2 MX 46
Group II base oil hydraulic fluid for industrial applications
ISO VG 46
| Property | Typical value | Limit | Method |
|---|---|---|---|
| Specific gravity @15°C | 0,877 | ASTM D 4052 | |
| Kinematic viscosity at 40°C, cSt | 46 | ±10% | ASTM D 445 |
| Kinematic viscosity at 100°C, cSt | 6,8 | ASTM D 445 | |
| Viscosity index | 102 | ASTM D 2270 | |
| Flash point, °C | 220 | Report | ASTM D 92 |
| Pour point, °C | -33 | ASTM D 97 | |
| TAN, mgKOH/g | 0,08 | ASTM D 664 | |
| FZG, failure load stage | 12 | Min. 10 | ISO 14635-1 |
| Water separability, 40/37/3 - mins | 15 | ASTM D 1401 | |
| Copper strip corrosion | 1b | Max. 2 | ASTM D 130 |
| TOST life, hours | >10000 | Min. 1000 | ASTM D 943 |
| Foam Sequence I, mL | 0/0 | 0/0 | Max. 150/0 |
| Foam Sequence II, mL | 0/0 | Max. 75/0 | ASTM D 892 |
| Foam Sequence III, mL | 0/0 | 0/0 | Max. 150/0 |
We email you this product's sheets in a single archive.

PETRONAS Hydraulic ZF 46 belongs to the premium performance, ashless PETRONAS Hydraulic ZF Series, specially created for a wide range of mobile and industrial hydraulic equipment operating under normal to heavy-duty conditions and in the presence of water that could otherwise cause filter blocking. It is recommended for systems with smaller reservoirs and coolers generating high thermal stress, systems sensitive to sludge and varnish formation with tight-tolerance pumps and servo valves, and systems demanding long-life lubricants. Formulated with high quality selected base oils and advanced zinc-free anti-wear, antioxidant, anti-rust and anti-foam additives, it delivers excellent anti-wear protection under demanding operating conditions and an oxidation life up to 5 times longer than standard fluids, with a TOST life exceeding 10,000 hours against a minimum requirement of 1,000 hours. Grade 46 has a kinematic viscosity of 46 cSt at 40°C and 6.8 cSt at 100°C, a viscosity index of 102, a flash point of 220°C and a pour point of -33°C. PETRONAS Hydraulic ZF Series meets or exceeds ASTM D6158 HM, DIN 51524 Part II HLP, ISO 11158 HM, Eaton E-FDGN-TB002-E, Fives Cincinnati P-68/P-69/P-70, Parker Denison HF-0/HF-1/HF-2, GB 11118.1 L-HM and SS 155434:2015 Type M.
ASTM D6158, type HM — antiwear hydraulic oil
The American standard for mineral hydraulic oils of type HM, that is, oils with antiwear additives. It is the ASTM counterpart of DIN 51524-2 HLP and ISO 11158 HM.
GB 11118.1 L-HM — hydraulic oil (China)
The Chinese national standard for hydraulic fluids; class L-HM is the antiwear oil, with a high-pressure variant.
Hydraulic oil HLP — DIN 51524, part 2
Part 2 of the German hydraulic fluid standard: HLP oils — mineral oils with oxidation, corrosion and antiwear additives. It is the most widely quoted reference in industrial hydraulics.
Eaton E-FDGN-TB002-E — hydraulic fluids
The Eaton technical bulletin listing the requirements for hydraulic fluids in Eaton and Vickers equipment, including the vane pump wear test.
Hydraulic oil, type H HM — ISO 11158
The international standard for mineral hydraulic fluids; class HM is the antiwear oil, the ISO counterpart of DIN 51524-2 HLP.
Fives Cincinnati P-68 — ISO VG 32 hydraulic oil
An approval number from the Fives Cincinnati list of fluids for use in its own machine tools. Approved hydraulic fluids must pass its own wear, filterability and water separation tests, beyond the DIN 51524-2 level.
Fives Cincinnati P-69 — ISO VG 68 hydraulic oil
An approval number from the Fives Cincinnati list of fluids for use in its own machine tools. Approved hydraulic fluids must pass its own wear, filterability and water separation tests, beyond the DIN 51524-2 level.
Parker Denison HF-0 — hydraulic fluid, most severe level
The most severe level of the Denison hydraulic fluid specification: the oil must pass the wear test on both a vane pump and a piston pump, dry and in the presence of water. HF-0 subsumes HF-1 and HF-2.
SS 15 54 34 — environmental requirements for hydraulic fluids (Sweden)
The Swedish standard requiring high biodegradability, low aquatic toxicity, and that the finished fluid not be classified as environmentally hazardous. It is required near groundwater and drinking water sources; verified products appear on the "SP list".
Parker Denison HF-2 — hydraulic fluid
The HF-2 level of the Denison specification, defined by the vane pump wear test. It is the base requirement for hydraulic oils in Denison equipment.
Eaton 03-401-2010 — hydraulic fluids
Eaton's hydraulic fluid specification for its own pumps and motors, which unified the former Vickers I-286-S and M-2950-S requirements.