Idraulicar HVI 46
HVLP hydraulic oil for high- and low-pressure industrial and mobile systems
ISO VG 46
| Property | Typical value | Limit | Method |
|---|---|---|---|
| Specific gravity @15°C | 0,877 | ASTM D 4052 | |
| Kinematic viscosity at 40°C, cSt | 46 | ±10% | ASTM D 445 |
| Kinematic viscosity at 100°C, cSt | 8,0 | ASTM D 445 | |
| Viscosity index | 146 | Min. 140 | ASTM D 2270 |
| Flash point, °C | 220 | ASTM D 92 | |
| Pour point, °C | -33 | ASTM D 97 | |
| TAN, mgKOH/g | 0,08 | ASTM D 664 | |
| FZG, Stages passed | >12 | Min. 10 | ISO 14635-1 |
| Water separability, 40/37/3 - mins | 15 | ASTM D 1401 | |
| Copper strip corrosion | 1b | Max. 2 | ASTM D 130 |
| TOST life, hours | 9950 | Min. 1000 | ASTM D 943 |
| Foam Sequence I, mL | 0/0 | 0/0 | Max. 150/0 |
| Foam Sequence II, mL | 0/0 | Max. 75/0 | ASTM D 892 |
| Foam Sequence III, mL | 0/0 | 0/0 | Max. 150/0 |
We email you this product's sheets in a single archive.

PETRONAS Hydraulic HVZF 46 belongs to the premium performance, zinc-free, wear-resistant PETRONAS Hydraulic HVZF Series, specially created for a wide range of mobile and industrial hydraulic equipment operating under normal to heavy-duty conditions and in the presence of water that could otherwise cause filter blocking. It is recommended for hydraulic systems needing good control of fluid viscosity, systems subjected to high or rapid temperature variations, systems with smaller reservoirs and coolers generating high thermal stress, systems sensitive to sludge and varnish formation with tight-tolerance pumps and servo valves, and systems demanding long-life lubricants. Formulated with high quality selected base oils, a shear-stable VI improver and advanced zinc-free anti-wear, antioxidant, anti-rust and anti-foam additives, it delivers excellent anti-wear protection, more stable performance across a wide temperature range, and an oxidation life up to 10 times longer than the minimum ISO 11158 HV TOST requirement. Grade 46 has a kinematic viscosity of 46 cSt at 40°C and 8.0 cSt at 100°C, a viscosity index of 146, a flash point of 220°C and a pour point of -33°C. PETRONAS Hydraulic HVZF Series meets or exceeds DIN 51524 Part II HLP and Part III HVLP, ISO 11158 HV, Eaton Brochure 03-401-2010, Fives Cincinnati P-68/P-69/P-70 and Parker Denison HF-0/HF-1/HF-2.
Hydraulic oil HLP — DIN 51524, part 2
Part 2 of the German hydraulic fluid standard: HLP oils — mineral oils with oxidation, corrosion and antiwear additives. It is the most widely quoted reference in industrial hydraulics.
Vickers 35VQ25 vane-pump wear test
A vane-pump bench wear test (Eaton/Vickers) used to qualify anti-wear hydraulic fluids for high-pressure mobile pumps; a fluid 'meets 35VQ25' rather than being certified by Vickers itself.Source
Fives Cincinnati P-68 — ISO VG 32 hydraulic oil
An approval number from the Fives Cincinnati list of fluids for use in its own machine tools. Approved hydraulic fluids must pass its own wear, filterability and water separation tests, beyond the DIN 51524-2 level.
Fives Cincinnati P-69 — ISO VG 68 hydraulic oil
An approval number from the Fives Cincinnati list of fluids for use in its own machine tools. Approved hydraulic fluids must pass its own wear, filterability and water separation tests, beyond the DIN 51524-2 level.
Hydraulic oil, type H HV — ISO 11158
Class HV of ISO 11158: an antiwear hydraulic oil with a high viscosity index, for systems exposed to wide temperature swings.
Parker Denison HF-0 — hydraulic fluid, most severe level
The most severe level of the Denison hydraulic fluid specification: the oil must pass the wear test on both a vane pump and a piston pump, dry and in the presence of water. HF-0 subsumes HF-1 and HF-2.
Parker Denison HF-2 — hydraulic fluid
The HF-2 level of the Denison specification, defined by the vane pump wear test. It is the base requirement for hydraulic oils in Denison equipment.
Eaton 03-401-2010 — hydraulic fluids
Eaton's hydraulic fluid specification for its own pumps and motors, which unified the former Vickers I-286-S and M-2950-S requirements.